Service Manual 5007211_Evinrude E-TEC 75-90 HP Trim And Tilt [Servicing]

Produtos Relacionados:
Service Manual 5007211_Evinrude E-TEC 75-90 HP Trim And Tilt [Servicing]
5007211
BRP Marine

Sections:

  1. Disassembly
  2. Assembly

Disassembly

Thoroughly clean the unit before disassembling. Scrub all outside surfaces with a stiff brush and hot, soapy water to prevent surface dirt from contaminating internal parts.

Always use a lint free shop cloth when handling power trim/tilt components.

If painting the unit is required, paint it after it is completely assembled. Painting of individual components may cause flakes of paint to enter the hydraulic passages during assembly. Tape the trim/tilt piston rods before painting.

There may be high pressure behind some power trim valves. To avoid injury when removing manual release valve, be sure to cover valve with a shop cloth until the pressure is released. Wear safety glasses.

IMPORTANT: Before removing manual release valve, relieve pressure by fully extending cylinder. Screw the manual release valve in. Remove the retaining ring using a small pick or screwdriver. Discard the retaining ring.

Slowly remove the manual release valve. There may be pressure behind the valve—wear safety glasses.

Inspect the manual release valve. Discard the O-rings on the housing.

Remove the four large motor flange retaining screws. Remove the motor and discard O-ring, screws, and washers.

Remove drive coupler from either the motor or the pump assembly.

Assembly

IMPORTANT: Use only Evinrude/Johnson Bio degradable TNT Fluid to fill the hydraulic system.

Install drive coupler in pump assembly.

Install a new motor O-ring.

Position the motor on the manifold and install four new screws and lock washers. Tighten the screws 35 to 50 in. lbs. (4 to 6 N·m).

Oil O-rings and install them on the manual release valve. Oil and install the manual release valve. Tighten the valve to a torque of 45 to 55 in. lbs. (5 to 6 N·m).

Install new retaining ring in groove.