PREPARE-SE PARA O INVERNO: de 10 % a 50 % de desconto em todas as peças OEM!

A menos que seja proibido pelo fabricante. Não inclui produtos de reposição ou da marca Crowley Marine. Preço conforme marcado.

Contate-Nos
Procure por Mais de 1 Milhão de Peças Originais
Fáceis de usar  diagramas de peças Melhor preço  de garantia Especializado  suporte ao vivo Mais de 50 anos  servindo velejadores Enorme seleção de peças OEM  -  de 1950 a 2026 A maioria das peças em estoque  -  Cumprimento no mesmo dia
Peças em estoque- Realização no mesmo dia

Service Manual 25-30 HP E-TEC Electrical And Ignition [Timing Adjustments]

Produtos Relacionados:
Service Manual 25-30 HP E-TEC Electrical And Ignition [Timing Adjustments]
5007802
BRP Marine

Step 1: ELECTRICAL AND IGNITION

Thoroughly clean the crankshaft and flywheel tapers with Cleaning Solvent™ and let dry.

Align the flywheel keyway and install flywheel.

Coat the threads of the flywheel nut with Triple-Guard grease.

Install the washer and nut and tighten to a torque of 100 to 110 ft. lbs. (135 to 150 N·m).

Replace recoil starter.

IMPORTANT: Check ignition timing after flywheel removal or replacement. Refer to TIMING ADJUSTMENTS on p. 135.

Step 2: TIMING ADJUSTMENTS

Timing Pointer
The timing pointer on Evinrude E-TEC 25 – 30 HP models is not adjustable.

Timing Verification
Use Evinrude Diagnostics software to synchronize the mechanical timing of the outboard with the electronic timing of the EMM.


Ignition Timing Screen

Check ignition timing after any of the following procedures:

  • Powerhead replacement
  • Crankshaft replacement
  • Flywheel removal or replacement
  • CPS replacement
  • EMM replacement
  • EMM software replacement (reprogramming)

IMPORTANT: Make sure the timing pointer is set and the outboard reaches operating temperature before making any timing adjustments.

TPS Calibration
Use Evinrude Diagnostics software to tell the EMM what throttle position sensor voltage is when the throttle plates begin to open.

Remove the air silencer.

On the Settings screen of the diagnostics soft ware, click the “Set TPS Calibration” button.

  1. TPS Calibration button

While holding the throttle plates closed, advance the throttle linkage until it stops. The “Measured TPS Calibration” field on the screen will increase.

Click the “Working” button in the software to calibrate the TPS.

Install the air silencer.

Set TPS Calibration after replacing or adjusting any throttle body or throttle linkage parts.

Step 3: ELECTRIC STARTER SERVICING

Starter Removal

IMPORTANT: Do not clean the starter drive while the starter motor and drive are installed on the powerhead. The cleaning agent could drain into the starter motor, washing dirt from the drive into the starter bearings and commutator.

Disconnect the battery cables at the battery.

Remove lower motor covers. Refer to Lower Cover Removal on p. 75.

Remove the starter positive (+) cable from post on starter.

Remove three starter mounting screws. Remove the starter.

  1. Screws
Share on social:

Produtos Relacionados