PREPARE FOR WINTER: 10-50% discount on all OEM parts!

Unless prohibited by manufacturer. Does not include aftermarket or Crowley Marine branded products. Priced as marked.

Honoring all who served: veterans, active military and first responders save 5% on OEM parts all year round. Our warehouses and customer support are open on Veterans Day, November 11th.

Contate-Nos
Procure por Mais de 1 Milhão de Peças Originais
Fáceis de usar  diagramas de peças Melhor preço  de garantia Especializado  suporte ao vivo Mais de 50 anos  servindo velejadores Enorme seleção de peças OEM  -  de 1950 a 2026 A maioria das peças em estoque  -  Cumprimento no mesmo dia
Peças em estoque- Realização no mesmo dia

Service Manual 15-30 HP E-TEC Trim And Tilt [Troubleshooting]

Produtos Relacionados:
Service Manual 15-30 HP E-TEC Trim And Tilt [Troubleshooting]
5008146
BRP Marine

Routine Inspection

General

Check for external signs of fluid leakage. Correct causes as necessary.

Check the battery and make sure it is in good operating condition.

Reservoir Fluid

Check reservoir fluid level at least every three years or 300 operating hours. System capacity is approximately 15.2 fl. oz. (450 ml).

IMPORTANT: Use only Evinrude/Johnson Biodegradable TNT Fluid to fill the hydraulic system.

Refer to Trim and Tilt on p. 74 for filling procedure.

Manual Release Valve

Check the manual release valve with a torque wrench.

IMPORTANT: Tighten valve to a torque of 45 to
55 in. lbs. (5 to 6 N·m). Stern Brackets

Stern Brackets

Inspect the stern brackets for binding.

Tighten starboard tilt tube nut to a torque of 45 to 50 ft. lbs. (61 to 68 N·m).

Troubleshooting

Use the following guidelines to check a single piston trim/tilt unit that is not working correctly.

Cylinder Leakdown:

• Manual release valve seals
• External leaks

No reverse lock:

• External leaks

No operation, motor runs:

• Manual release valve open
• Fluid level low
• Pump coupler
• Hydraulic pump

No tilt down:

• Manual release valve
• Fluid level

Slow performance:

• Manual release valve
• Fluid level low
• Mechanical binding
• Electric motor
• Hydraulic pump

Unit locked in tilt up:

• Mechanical binding
• Hydraulic pump