Periodic Inspection And Adjustments [Battery] [1987]

Produtos Relacionados:

Applicable Models

Model group Year Model Serial
Yamaha Outboard 1984 - 1987 115hp All

Periodic Inspection And Adjustments [Battery] [1987]
LIT-18616-00-07
Yamaha Marine

Oil replacement

  1. Place an empty oil can under the gear case and remove the oil drain plug (lower) using a slotted-head screwdriver.

  2. Next, remove the oil level plug (upper).

  3. Inject outboard motor gear oil hypoid SAE #90 into the oil drain plug hole (lower).

  4. When the oil begins to flow out of the upper oil level plug hole, tighten the plug. Next, screw in the lower oil drain plug.

Replace the gear oil after the first 10 hours of operation and check the oil every 100 hours. If the gear oil becomes "milky" replace the gear oil.

BATTERY

  1. The fluid level should be between the upper and lower level marks. Use only distill ed water if refilling is necessary.

Normal tap water contains minerals which are harmful to a battery; therefore, refill only with distilled water.

The battery must be charged before use to ensure maximum performance. Failure to charge the battery properly before first use or a low electrolyte level will cause premature failure of the battery. Charging current: 4.0 amps/10 hrs or until the specific gravity reaches 1.280 at 20°C
(68°F).

Battery electrolyte is poisonous and dangerous, causing severe burns, etc. It contains sulfuric acid. Avoid contact with skin, eyes, or clothing.
Antidote: EXTERNAL — Flush with water.
INTERNAL — Drink large quantities of water or milk. Follow with milk of magnesia, beaten egg, or vegetable oil. Call physician immediately.
Eyes: Flush with water for 15 minutes and get prompt medical attention. Batteries produce explosive gases. Keep sparks, flame, cigarettes, etc. away. Ventilate when charging or using in closed space. Always shield eyes when working near batteries.
KEEP OUT OF REACH OF CHILDREN.