PRÉPAREZ-VOUS POUR L'HIVER : de 10 % à 50 % de réduction sur toutes les pièces d'origine !

Sauf interdiction par le fabricant. N'inclut pas les produits de rechange ou de marque Crowley Marine. Prix indiqué.

Recherche Plus d'un 1 million de pièces d'équipementier
Facile à utiliser  schémas des pièces Meilleur prix  garanti Assistance en directexperte   Plus de 50 ans  au service des plaisanciers Grand choix de pièces OEM  -  de 1950 à 2026 La plupart des pièces en stock  -  Exécution le jour même
Pièces en stock- Exécution le même jour

Service Manual 25-30 HP E-TEC Electrical And Ignition [Stator Tests]

Produits associés:
Service Manual 25-30 HP E-TEC Electrical And Ignition [Stator Tests]
5007802
BRP Marine

STATOR TESTS

The stator consists of 2 windings (6 poles each) on a 5 inch diameter core and generates an out put voltage of 55 VAC (700 watts maximum). This voltage is converted by the Battery Charge Module to provide 12 VDC for battery charging (approximately 8 A at 500 RPM and 15 A from 3000 RPM to WOT) and 55 VDC for fuel injector, and fuel and oil pump operation.

Stator Resistance Tests

Use a digital multimeter to check resistance of stator windings.

Disconnect stator (4-pin) connector from the engine harness (4-pin) connector.

Yellow & Yellow / white 1.0 ± .020 Ω @ 73°F (23°C)
Brown & Brown / white 1.0 ± .020 Ω @ 73°F (23°C)

1.Stator connector

Connect meter leads to the following pins:

  • Yellow/white and yellow (pins 1 and 2)
  • Brown/white and brown (pins 3 and 4)

IMPORTANT: A reading of less than 2 ohms is acceptable. Make sure meter is calibrated to read 1 ohm or less.

To check for a grounded winding, connect one meter lead to ground and alternately connect the other meter lead to each stator wire. Meter should read no continuity. If meter reads continuity, replace stator.

Stator Voltage Output Test

Use a digital multimeter to check stator output voltage. Set meter to read 110 VAC output.

To prevent accidental starting of outboard, disconnect crankshaft position sensor (CPS).

Disconnect CPS.

Disconnect stator (4-pin) connector from the engine harness (4-pin) connector.

Connect Stator Test Adaptor tool, P/N 354719, to stator connector.

Connect meter leads to terminals of adaptor tool. With a fully charged battery, crank outboard (300 RPM minimum) and observe meter reading:

  • 55 VAC above 500 RPM

1.Stator Test Adaptor

IMPORTANT: Rope start models can be tested using a Peak Reading Voltmeter, set to the 50 VAC scale. Remove spark plugs and rotate fly wheel with the starter rope, using a long, steady pull. Voltage should be approximately 30 VAC.

Share on social:

Produits associés