EXPLODED DIAGRAM

REMOVAL AND INSTALLATION CHART
| Step | Procedure/Part name | Q'ty | Service points |
|---|---|---|---|
| WATER PUMP REMOVAL | Follow the left "Step" for removal. | ||
| Lower unit assembly | Refer to the "LOWER UNIT REMOVAL" section. | ||
| 1 | Bolt (with washer) | 2 | 8 x 55 mm |
| 2 | Bolt (with washer) | 2 | 8 x 45 mm |
| 3 | Water pump upper housing | 1 | NOTE:When installing the water pump housing,align the hole in it with the projection in the insert cartridge. |
| 4 | Insert cartridge | 1 | NOTE:When installing the cartridge, turn the drive shaft clockwise. |
| 5 | Cartridge inner plate | 1 | |
| 6 | Impeller | 1 | |
| 7 | Woodruff key | 1 | |
| 8 | Water pump gasket | 1 | |
| 9 | Cartridge outer plate | 1 | |
| 10 | Cartridge gasket | 1 | |
| 11 | Dowel pin | 2 | |
| 12 | Water pump lower housing | 1 | |
| 13 | Water pump gasket | 1 | |
| 14 | O-ring | 1 | |
| 15 | Oil seal | 2 | |
| Reverse the removal steps for installation |
SERVICE POINTS
Water pump housing inspection
- Inspect:
- Water pump housing
Crack/Damage -> Replace.
Impeller and insert cartridge inspection
- Inspect:
- Impeller
- Insert cartridge
Crack/Damage -> Replace.