INSPECTION
All measuring instruments should be handled with special care, or the correct measurement is impossible.
On an instrument powered by dry batteries, they should be checked for voltage periodically and replaced, if necessary.
NOTE: "O—O" indicates the terminals between which there is a continuity of electricity; i.e., a closed circuit at the respective switch position.
Low resistance measurement
When measuring the resistance of 10 Ω or less using the digital tester, the correct measurement cannot be obtained because of the tester's internal resistance.
To obtain the correct value, subtract this internal resistance from the displayed measerement.
Correct value = Displayed measurement - Internal resistance
NOTE: The internal resistance of the tester can be obtained by connecting both of its terminals.