OVER-REVOLUTION CAUTION SYSTEM
Only for DF50
From the middle of 2004 year model, the over revolution limiter rpm have been changed from approx. 7 000 r/min to 6 700 r/min.
In accordance with this change, ECM has been changed.
SAFETY RELAY SYSTEM
Safety relay system is to avoid operating the starter motor when the engine is already operating.
The starter motor relay will only engage when the ignition switch is turned to the “START” position if the all of the following conditions are satisfied:
• Lock plate is attached to emergency stop switch.
• Neutral switch is in “ON” position.
• Engine is not already operating.
In accordance with this change, ECM has been changed.
FLYWHEEL MAGNETO AND CRANKSHAFT
• The flywheel bolt has been changed from M16 to M14.
• The washer has been changed in inside diameter.
• In accordance with change of the flywheel bolt, tightening torque of flywheel bolt has been changed.
• The flywheel side of the crankshaft has been changed in machining.

These modification have been carried out from the middle of 2004 year model.