INSPECTION FOR RESISTANCE

09930-99320 : Digital tester
Tester range : Ω (Resistance)
Make sure ignition switch is always OFF when measuring resistance.
(1) Disconnect battery cables from battery.
(2) Disconnect all wires from ECM.
(3) Connect the tester probes to terminal of wire harness side, and measure resistance according to the “RESISTANCE TABLE".
RESISTANCE TABLE


1: Disconnect remote control wire harness, and connect tester probe to terminal (A) (Gray wire).
OTHER INSPECTION

FUEL INJECTOR OPERATING SOUND (CRANKING)
(1) Touch a sound scope or long blade screw driver to fuel injector body as shown.
(2) Crank engine and check for injector operating sound.
Injector operating sound : “Click”

FUEL INJECTOR OPERATING SOUND (INDIVIDUAL)
(1) Disconnect fuel injector wire, and connect the test cord.
09930-89260 : Injector test cord A
(2) Connect Gray wire to body ground.
(3) Momentarily touch Black/Yellow wire to starter motor relay right terminal (connected to battery positive (+) terminal), and check for injector operating sound.
Injector operating sound : “Click”
Connecting fuel injector to battery positive for more than a few seconds may cause injector overheating and possible injector solenoid failure.
FUEL INJECTOR OPERATING SIGNAL
09930-89930 : 8-pin test cord
Peak voltmeter Stevens CD-77
Tester range : NEG5O

(1) Connect the test cord as shown, then turn ignition switch ON.
(2) Connect the tester probe (-) (Black) to starter motor relay right terminal (connected to battery positive (+) terminal) as shown.