ECM

The program (internal circuit) of ECM has been changed.
This change is performed by following reasons:
Addition of the IAC valve fixing mode.
Accommodation of the optional digital gauges (Teleflex gauges).
| Part Name | Early (’07 model)Part Number | Interchange-ability | Late (’08 model)Part Number |
|---|---|---|---|
| ECM (DF40_E01) | 33920-87J92 | Yes ← → No | 33920-87J93 |
| ECM (DF40_E03) | 33920-87JA2 | Yes ← → No | 33920-87JA3 |
| ECM (DF50_E01) | 33920-87JB2 | Yes ← → No | 33920-87JB3 |
| ECM (DF50_E03, E40) | 33920-87JC2 | Yes ← → No | 33920-87JC3 |
WIRING HARNESS

- The shape of the SDS communication connector has been changed, as shown in the figure, to connect SDS-Ver.5 without conversion harness.
- The optional digital gauge operating signal is output from the three lead wires in this connector. For this reason, when the
optional gauge (Teleflex gauge) is used, the connector (A) for
the standard gauge in the wiring harness in the figure should
be connect with the SDS communication connector.

1 SDS Communication connector for SDS or optional digital gauge.