ELECTRICAL AND IGNITION

Key Switch, START Position

Key switch START:

  • Switches 12 V to terminal “S” of key switch and to the neutral safety switch (in remote control).
  • A closed neutral safety switch provides 12 V to the engine wire harness yellow/red wire and terminal 26 of EMM J-1A connector.
  • EMM grounds brown/white wire to activate solenoid.

  1. Ignition switch, START position – Continuity between terminals “B” and “A”; “B” and “S”
  2. Terminal “S”, 12 V
  3. Neutral safety switch

ELECTRIC START TESTS

Starter Solenoid Test

Disconnect the B+ (POS) battery cable at the battery.

IMPORTANT Disconnect all wiring from solenoid terminals before proceeding with this test. Use a digital multimeter to measure resistance.

Put one meter lead on the starter positive (+) cable terminal and the other lead on the battery positive (+) cable terminal:

  • Meter must not show continuity (high reading).
  • If meter shows continuity (low reading), replace the solenoid.

  1. “A” terminal, B+ (purple)
  2. “B” terminal, NEG (brown/white)
  3. Starter positive (+) cable terminal
  4. Battery positive cable (B+) terminal

Apply B+ to terminal “A” of solenoid and ground (NEG) to terminal “B” of solenoid. Measure resistance between the starter positive (+) cable terminal and the positive battery (+) cable terminal.

  • The solenoid must close with an audible click.
  • Meter must show continuity (low reading).
  • If meter shows no continuity (high reading), replace the solenoid.

After re-installing the solenoid, coat all wires and terminals with Black Neoprene Dip.

No Load Current Draw Test

Securely fasten starter in a vise or suitable fixture before proceeding with this check.

Use a battery rated at 500 CCA (60 amp-hr) or higher that is in good condition and fully charged.

IMPORTANT The driven gear and pinion assembly must be removed for this test.

Use an inductive ammeter or connect a 0 to 100 amp ammeter in series with a heavy jumper between the battery positive (+) terminal and the starter positive (+) terminal.

Fluke model 334 or 336, Snap-On model MT110 or EETA501, and various other ammeters should be available through local tool suppliers.

Attach or hold a vibration tachometer, such as a Frahm1 Reed tachometer, to the starter.

TYPICAL

Complete the circuit with a heavy jumper between the battery negative (–) terminal and the starter frame.

Monitor the starter RPM and current draw.

  • At 10,500 RPM the ammeter should show a maximum of 30 A.