EXPLODED DIAGRAM

REMOVAL AND INSTALLATION CHART
| Step | Procedure/Part name | Q'ty | Service points |
|---|---|---|---|
| THERMOSTAT REMOVAL | Follow the left "Step" for removal. | ||
| Oil level plug | |||
| 1 | Hose | 1 | |
| 2 | Bolt with washer (thermostat cover) | 3 | |
| 3 | Thermostat cover | 1 | |
| 4 | Gasket (thermostat) | 1 | Not reusable |
| 5 | Thermostat | 1 | |
| 6 | Screw (cylinder anode) | 1 | |
| 7 | Cylinder anode | 1 | |
| Reverse the removal steps for installation. |
SERVICE POINTS


Thermostat inspection
- Measure:
Valve operating temperature
Valve lift (a)
Out of specification -> Replace the thermostat.
| Water temperature | Valve lift |
|---|---|
| Below 58 ~ 62C (136.4 ~ 143.6F) | 0 mm (0 in) |
| Above 70°C (158F) | 3 mm (0.12 in) |
Measuring steps:
Suspend the thermostat in a container filled with water.
Slowly heat the water.
Place a thermometer in the water.
While stirring the water, observe the thermometer's indicated temperature.
Anode inspection
- Inspect:
- Anode
Refer to "ANODE" in chapter 3.