Starter motor

| No. | Part name | Q’ty | Remarks |
|---|---|---|---|
| 1 | Starter motor | 1 | |
| 2 | Bolt | 3 | M8 x 45 mm |
| 3 | Nut | 1 | |
| 4 | Holder | 2 | |
| 5 | Plastic tie | 2 | |
| 6 | Bolt | 1 | M8 x 16 mm |
| 7 | Terminal | 1 | |
| 8 | Bolt | 1 | M8 x 20 mm |
| 9 | Terminal stud bolt | 1 | |
| 10 | APS | 1 | |
| 11 | Collar | 3 | |
| 12 | Grommet | 3 | |
| 13 | Bolt | 3 | M6 x 35 mm |
| 14 | Bolt | 1 | M6 x 16 mm |
Removing the starter motor
- Disconnect the starter motor lead (a), and then remove the plastic ties (1) and holders (2).

Remove the junction box wiring harness extension terminal (b), and then remove the starter motor (3).
Remove the junction box wiring harness extension terminal (c), terminal (4), and terminal stud bolt (5).

Installing the starter motor
Install the terminal (1), junction box wiring harness extension terminal (a), and terminal stud bolt (2), and then tighten the terminal stud bolt to the specified torque.
Install the starter motor (3), and then install the junction box wiring harness extension terminal (b).

Terminal stud bolt (2): 26 N-m (2.6 kgf m, 19.2 ft lb)
- Connect the starter motor lead (c) and brown lead of the wiring harness, and then fasten the starter motor lead using the holders (4) and plastic ties (5).

TIP:
To fasten the starter motor lead, see “Wiring harness routing” (5-6).