REMOVING/INSTALLING THE OXYGEN DENSITY SENSOR

| Order | Job/Part | Q'ty | Remarks |
|---|---|---|---|
| 1 | Plastic locking tie | 1 | Not reusable |
| 2 | Rubber cap | 1 | |
| 3 | Bolt | 2 | |
| 4 | Oxygen density sensor cover | 1 | |
| 5 | Bolt | 1 | |
| 6 | Bolt | 1 | |
| 7 | Bolt | 1 | |
| Continued on next page. |

| Order | Job/Part | Q'ty | Remarks |
|---|---|---|---|
| 8 | Oxygen density sensor assembly | 1 | |
| 9 | Gasket set | 1 | Not reusable |
| 10 | Oxygen density sensor bracket | 1 | |
| 11 | Oxygen density sensor | 1 | Refer to "CHECKING THE OXYGEN DENSITY SENSOR" on page 8-25 |
| 12 | Oxygen density sensor joint | 1 | |
| For installation, reverse the removal procedure. |
INSTALLING THE OXYGEN DENSITY SENSOR

Install:
- Bolts (1) (2) (3)
Bolt
14 Nm (1.4 m-kgf, 10 ft-lb)
NOTE: