EXPLODED DIAGRAM

REMOVAL AND INSTALLATION CHART
| Step | Procedure/Part name | Q'ty | Service points |
|---|---|---|---|
| ELECTRICAL UNIT DISASSEMBLY | Follow the left "Step" for removal. | ||
| Electrical unit | Refer to "ELECTRICAL UNIT REMOVAL" | ||
| 1 | Bolt | 2 | M8 x 25 mm |
| 2 | Starting motor | 1 | |
| 3 | Bolt | 2 | M6 x 20 mm |
| 4 | CDI unit | 1 | |
| 5 | Bolt | 2 | M6 x 25 mm |
| 6 | Rectifier regulator | 1 | |
| 7 | Bolt | 1 | M6 x 14 mm |
| 8 | Bracket | 1 | |
| 9 | Socket | 1 | |
| 10 | Starter relay | 1 | |
| 11 | Bolt | 2 | M6 x 25 mm |
| 12 | PTT relay | 1 | |
| Reverse the removal steps for installation. |