BACKLASH MEASUREMENT
Do not install the water pump components when measuring the backlash.
Forward gear backlash

- Measure:
- Forward gear backlash
Out of specification -> Adjust.
Backlash: 0.27~ 0.99 mm
Measuring steps:
- Attach the backlash indicator on the drive shaft (11 mm in diameter).
Backlash indicator: YB-06265/90890-06265
- Attach the dial gauge on the gear case, and make the dial gauge stem contact the mark on the indicator.
Backlash adjusting plate: YB-07003
Dial gauge: YU-03097/90890-01252
Magnetic flexible stand: YU-34481/90890-06705
- While pulling the drive shaft and pushing the propeller shaft, slowly turn the drive shaft clockwise and counterclockwise; then, measure the backlash when the drive shaft stops in each direction.
- Adjust:
- Forward gear shim
Adjust the shim to be added or removed according to specification.
| Forward gear backlash | Shim thickness |
|---|---|
| Less than 0.27 mm | To be decreased by (0.63 - measurement) x O.47 |
| More than 0.99 mm | To be increased by (measurement - 0.63) x O.47 |
Available shim thickness: 0.30, 0.40 and 0.50 mm