LOWER UNIT LEAKAGE CHECK
LOWER UNIT LEAKAGE CHECK
1) Tighten the gear oil-drain screw, and connect the tester to the oil-level hole.
2) Pump the tester, and apply a pressure of 1.0 kgf/sq.cm (1.020 bar)
3) Check that the pressure is held at 1.0 kgf/sq.cm (1.020 bar) for 10 seconds.
NOTE: _____
If the pressure falls, the leakage from lower unit is unacceptable, requiring re-inspection of its component parts.

INSTALLATION
INSTALLATION
1) Grease the spline of the drive-shaft and the water-tube outer face, align the water-tube and drive-shaft, install the lower unit and tighten the bolts to the specified torque.
Installation bolts, specified torque:
6-9.5 Nm
(0.6-0.95 m-kg, 4.3-6.9 ft-lb)
2) Connect the shift-rod.
3) Fill with fresh gear oil through the oil plug hole until oil flows out through the level plug hole, then secure the plugs in these two holes (the level plug first).