LOWER UNIT LEAKAGE CHECK
- Check:
- Pressure
Impossible to maintain the specified pres sure for 10 seconds -> Reinstall.
Using the special service tool.
Checking steps:
- Attach the Mity Vac to the oil level hole.
Mity Vac (1): YB-35956, 90890-06756
- Apply the specified pressure.
Specified pressure: 100 kPa (1.0 m kg, 14.2 psi)
If the pressure falls, the leakage from lower unit is unacceptable, requiring re-inspection of its component parts.

INSTALLATION
LOWER UNIT
- Install:
- Dowel pin (1)
- Lower unit (2)
- Bolt (3)
• Apply marine grease or equivalent to the matching surfaces as shown.
• Set the shift cam to the reverse position.
• Hold the shift rod nut in the lowest position.
• Insert the drive shaft into the crankshaft, insert the water tube into the water seal, and insert the shift rod into the upper casing.
Lower unit mounting bolt: 37 N•m (3.7 kg•m, 26.8 ft•lb)