PREPARATION FOR REMOVAL
• Disconnect electrical lead.
• Disconnect the fuel hose and delivery pipe.
EXPLODED DIAGRAM

Extent of removal:
(1) Prime Starter removal
(2) Electromagnetic valve removal
(3) Diaphragm removal
(4) Manual valve disassembly
(5) Prime starter disassembly

INSPECTION
The test can be done without removing the Prime Starter from the power unit.
- Check:
- Leakage
Out of specification → Replace.
- Leakage

Checking steps:
- Disconnect the outlet hoses and leads.
- Attach the Mity-vac as shown.
Mity-vac: YB-35956, 90890-06756
- Apply the specified pressure.
Specified pressure: 100 kPa (1.0 kg/cm², 14.2 psi)
Period: 10 seconds
- Check that the pressure is maintained.
- Check:
- Electromagnetic valve operation
Out of specification → Replace.
- Electromagnetic valve operation
Checking steps:
- Attach the Mity-vac and apply the specified pressure.
Specified pressure: 100 kPa (1.0 kg/cm², 14.2 psi)
- Connect the battery.
(1) Yellow lead → Positive terminal
(2) Purple (Purple/White) → Negative terminal
- Check that the pressure is suddenly released.