OIL PRESSURE SWITCH

Connect MITYVAC.
Connect a tester between the terminal and case.
Apply specified pressure.
Replace the pressure switch if it is out of specification.
Pressure condition:
Applied 0.6 ± 0.2 kg/cm ....... Discontinuity
Released 0.0 kg/cm .......Continuity
BATTERY
Refer to page 3-9.
INSTALLATION
FLYWHEEL MAGNETO

- Install:
• Dowel pin (1)
• CDI magneto base (2)
• Screw (3)
• Woodruff key (4)
• CDI magneto (5)
• Washer (6)
• Flywheel nut (7)

Flywheel nut: 100 Nm (10 m⋅kg, 72 ft⋅lb)