IGNITION SYSTEM INSPECTION
CAUTION:
All measuring instruments should be handled with special care, or the correct measurement is impossible.
On an instrument powered by dry batteries, they should be checked for voltage periodically and replaced, if necessary.
SPARK PLUG

- Inspect:
- Electrode (1)
Wear/Damage -> Replace.
- Insulator color (2)
Normal condition is a medium to light tan color.
Distinctly different color -> Check the engine condition.
- Spark plug type
Incorrect -> Replace.
Standard spark plug:
C30MH model: NGK BR8HS-10 (CANADA)
C30ER model: NGK B8HS-10 (USA), NGK BR8HS-10 (CANADA)
Refer to the "PERIODIC SERVICE-SPARK PLUG" section in CHAPTER 3. (page 3-23)
SPARK PLUG CAP

- Inspect:
- Spark plug cap (1)
Crack/Damage -> Replace.
- Replace:
- Spark plug cap


Replacement steps:
Remove the spark-plug cap by pulling the cap, and remove the plug-cap spring from the high-tension cable.
Cut about distance (a) off the end of the high-tension cable.
Distance (a): 5 mm (0.2 in)
Referring to the diagram, strip about 5 mm (0.2 in) of the insulation off the end of the high-tension cable, and fit the plug capspring.
Push the cap-spring into the plug-cap.
(1) Bend
(2) Contact
IGNITION COIL

- Inspect:
- Ignition coil (1)
Crack/Damage -> Replace.
- Measure:
- Ignition coil resistance
Out of specification -> Replace.
A


Measurement steps:
Disconnect the ignition coil lead Black/White (B/W) from the wire harness.
Connect the tester to the ignition coil as shown.
Digital multi meter: YU-34899-A, 90890-06752
Primary coil [A]:(Ωx1)
- Tester (+) lead -> Black/White (B/W) (1)
- Tester (-) lead -> Ground lead (B)
Secondary coil [B]: (Ωx1K)
Tester (+) lead -> High tension cord (1)
Tester (-) lead -> Ground lead (B)
Measure the primary and secondary coil resistance.
Primary coil resistance:
Black/White (B/W) - Black (B) 0.18-0.24Ω at 20°C (68°F)
Secondary coil resistance: High tension cord — Black (B) 2.7 —3.7kΩ at 20°C (68°F)
ENGINE STOP SWITCH

- Check:
- Engine stop switch continuity
Out of specification -> Replace.
Checking steps:
Disconnect the White (W) and Black (B) leads from the wire harness.
Connect the tester (Ωx1) to the stop switch as shown.
Digital multi meter: YU-34899-A, 90890-06752
Remove the lock-plate and check for continuity according to the chart below.
Install the lock-plate, and push the button to see that there is continuity.
IGNITION SPARK GAP

WARNING
While taking spark check be careful not to touch any connection of lead wires of the "ignition spark gap tester".

WARNING
- When doing the spark test, take special care not to allow leakage from the removed plug cap.
- This check is likely to produce sparks, so be sure that no flammable gas or fluid is in the vicinity.

- Check:
- Ignition spark gap
Out of specification -> Replace.


Checking steps:
- Adjust the spark gap to 11 mm by turning the adjust knob.
NOTE:
Be careful so that the spark gap does not come excessively off the measuring position (11 mm).
- Connect the spark plug cap to the spark gap tester. Then remove the spark plugs from the engine.
Spark gap tester: YM-34487, 90890-06754
- Check that when the starter rope is pulled briskly, it gives a blue strong spark.
Minimum spark gap: 8 mm (0.31 in)

NOTE:
Engine operation test:
- Connect the fuel hoses and keep the throttle opened.
- The test should be made with the anti-cavitation plate submerged. Otherwise, the water pump impeller will heat up and be damaged, should not the engine be raced.
(1) Dynamic spark tester (spark gap tester)
(2) Plug cap
(3) Spark plug
CHARGE COIL

- Measure:
- Charge coil resistance
Out of specification -> Replace.
Refer to the "REMOVAL AND INSTALLATION-CDI MAGNETO ASSEMBLY" section. (page 8-6)
Measurement steps:
Disconnect the Brown (Br) and Blue (L) leads from the wire harness.
Connect the tester (Ω x 100) to the charge coil as shown.
Digital multi meter: YU-34899-A, 90890-06752
Tester (+) lead -> Brown (Br) lead
Tester (-) lead -> Blue (L) lead
- Measure the charge coil resistance.
Charge coil resistance: Brown (Br) — Blue (L) 401-490Ω at 20°C (68°F)
PULSER COIL

- Measure:
- Pulser coil resistance
Out of specification -> Replace.
Refer to the "REMOVAL AND INSTALLATION-CDI MAGNETO ASSEMBLY" section. (page 8-6)
Measurement steps:
Disconnect the White/Red (W/R), White/Black (W/B) and Black (B) leads from the wire harness.
Connect the tester (Ω x 100) to the pulser coil as shown.
Digital multi meter: YU-34899-A, 90890-06752
Pulser coil 1
Tester (+) lead -> White/Red (W/R) lead
Tester (-) lead -> Black (B) lead
Pulser coil 2
Tester (+) lead - White/Black (W/B) lead
Tester (-) lead -> Black (B) lead
- Measure the pulser coil resistance.
Pulser coil resistance:
Pulser coil 1: White/Red (W/R) - Black (B) 311—381Ω at 20°C (68°F)
Pulser coil 2: White/Black (W/B) - Black (B) 311—3810 at 20°C (68°F)
CDI UNIT

- Measure:
- CDI unit (1) resistance
Out of specification -> Replace.
NOTE:
- Digitaltester can not be used for this inspection. Use analogue tester.
- CDI resistance values will vary from meter to meter, especially with electronic digital meters. For some testers, polarity of leads is reversed.
Measurement steps:
Disconnect the CDI unit lead from the wire harness.
Connect the Pocket tester (Ωx 1K) to the CDI unit as shown.
Pocket tester: YU-03112, 90890-03112
- Measure the CDI unit resistance.
NOTE:
There is a point at which the pointer swings greatly and swings back. Read the point where the point has returned to stop.

W : White
B : Black
B/O : Black/ Orange
B/W : Black/White
B : Black
W/R : White/Red
W/B : White/Black
Br : Brown
L : Blue
CDI SYSTEM
NOTE:
- If there is no spark, or the spark is weak, continue with the CDI test.
- If a good spark is obtained, the problem is not with the CDI system, but possibly the spark plug or other component is defective.
- Use the following special tool in this inspection.

CDI tester(1): YU-91022-B
- If lamp does not light, check tester batterys. If they are installed correctly and are good, check the clip leads for faulty connections. If no fault can be found, refer to the warranty statement for instructions for sending the tester back to Electro-Specialities, inc.
WARNING
While taking CDI unit check be carefull not to touch any connection of lead wires of the "CDI tester".


- Check:
- CDI tester for high scale
No indication -> Replace the tester.
Checking steps:
- Place switch (1) in HIGH position.
- Plug the capacitive clip (2) into an electric outlet. (117 VAC for ten seconds)
WARNING
Do not touch te plug pins on the capacitive clip while plugging it and depressing the button. A electric shock will result.
Remove the capacitive clip from the outlet.
Set the tester dial (3) to 50, or below.
Connect the capacitive clip.
Yellow (Y) lead -> Capacitive clip N terminal.
Red (R) lead -> Capacitive clip P terminal.
The indicator lamp on the tester should light.
Depress the button on the simulator.

- Check:
- CDI tester for low scale
No indication -> Replace the tester.
Checking steps:
Place switch (1) in LOW position.
Set the tester dial (2) to 50, or below.
Connect the 12 V battery.
Yellow (Y) lead -> Negative terminal.
Red (R) lead -> Positive terminal.
- The indicator lamp on the"tester should light.

- Check:
- CDI unit output (test #1)
No indication -> Replace.
Repeat test three times.
Checking steps:
Disconnect the Black/Orange (B/0) leads from the ignition coil.
Remove the spark plugs.
Connect the CDI tester (1) and load coil (2) to CDI unit (3) as shown.
CDI tester: YU-91022-1
Load coil: YU-91022-3
NOTE:
In this test, connect the load coil, provided along with the tester, between the CDI unit output and the ground.
- Set the tester switch and dial to specified.
| Range switch | Dial setting |
|---|---|
| H | 65 Use load coil |
- Cranking the engine.
NOTE:
- The coil output varies greatly cranking speed.
- Cranking the cold engine with the plugs in and a weak battery cannot be found proper readings.

- Check:
- Charge coil output (test #2)
Repeat test three times.
No indication -> Replace.
Checking steps:
Disconnect the Brown (Br) and Blue (L) leads from the charge coil.
Remove the spark plugs.
Connect the CDI tester (1) to charge coil (2) as shown.
CDI tester: YU-91022-1
- Set the tester switch and dial to specified.
| Range switch | Dial setting |
|---|---|
| H | 75 |
- Cranking the engine.
NOTE:
- The coil output varies greatly cranking speed.
- Cranking the cold engine with the plugs in and a weak battery cannot be found proper readings.

- Check:
- Pulser coil output (test #3)
Repeat test three times.
No indication -> Replace.
Checking steps:
Disconnect the White/Red (W/R) and Black (B) leads from the pulser coil.
Remove the spark plugs.
Connect the CDI tester (1) to pulser coil (2) as shown.
CDI tester: YU-91022-1
- Set the tester switch and dial to specified.
| Range switch | Dial setting |
|---|---|
| L | 50 |
- Cranking the engine.
NOTE:
- The coil output varies greatly cranking speed.
- Cranking the cold engine with the plugs in and a weak battery cannot be found proper readings.
LIGHTING COIL
- Measure:
- Lighting coil resistance
Out of specification -> Replace.
Refer to the “REMOVAL AND INSTALLATION-CDI MAGNETO ASSEMBLY" section. (page 8-6)
Measurement steps:
- Disconnect the Green (G) leads from the wire harness.
- Connect the tester (Ωx1) to the lighting coil as shown.
Digital multi meter: YU-34899-A, 90890-06752
Tester (+) lead -> Green (G) lead
Tester (-) lead -> Green (G) lead
- Measure the lighting coil resistance.
Lighting coil resistance: Green (G) — Green (G) 0.31-0.37 Ω at 20°C (68°F):
RECTIFIER [ELECTRIC STARTER MODEL]

- Check:
- Continuity of rectifier (1)
Out of specification -> Replace.
Checking steps:
Disconnect the Green (G), Red (R) and Black (B) leads from the wire harness.
Connect the Pocket tester (Ωx1) to the rectifier as shown.
NOTE:
Digital tester can not be used for this inspection.
Pocket tester: YU-03112, 90890-03112
- Check the continuity of the rectifier.