IGNITION CONTROL SYSTEM

(1) Thermo switch
(2) CDI unit
(3) Oil level warning lamp
(4) Oil level sensor
(5) Meter
(A) 40TR
(B) 50TR
Y/R : Yellow/Red
P : Pink
O : Orange
O/G : Orange/Green
B : Black
Gy : Gray
THERMO SWITCH

- Measure:
- Thermo switch continuity
Out of specification —> Replace.
Thermo switch continuity temperature:
Orange (O) —Orange/Green (O/G)
(a) 38 ~ 52’C (100.4 ~ 125.6“F)
(b) 26 ~ 34°C (78.8 ~ 93.2°F)
Pink (P) — Black (B)
(a) 90 ~ 96°C (194.0 ~ 204.8 F)
(b)> 76 ~ 90°C (168.0 ~ 194.0°F)

(1) Discontinuity
(2) Continuity
(3) Discontinuity
(A) Temperature
(B) Time
Measuring steps:
- Suspend thermostat in a vessel.
- Place reliable thermometer in a water.
- Heat water slowly.
- Observe thermometer, while stirring water continually.
OIL LEVEL SENSOR

- Measure:
- Oil level sensor continuity
Out of specification —» Replace.



WARNING LAMP

- Check:
- LED (Light emitting diode) lighting
No lighting -> Replace.
Battery voltage: 1.5 V
Yellow/Red lead —> Positive terminal.
Pink lead —> Negative terminal.
Use only originally pen light battery (1.5 V), other than batteries such as alkaline battery I higher voltage one will be burnt the diode.
LED has an direction for electrical current. Therefore try reverse connection if there is no lighting.
OIL LEVEL WARNING LAMP

- Check:
- LED (Light emitting diode) lighting
No lighting -> Replace.
Battery voltage: 1.5 V
Green LED
Yellow/Red lead —> Positive terminal.
Green lead —> Negative terminal.
Orange LED
Yellow/Red lead —> Positive terminal.
Black lead —> Negative terminal.
Red LED
Yellow/Red lead —> Positive terminal.
Green/Red lead -> Negative terminal.
Use only ordinally pen light battery (1.5 V), other than batteries such as alkaline battery I higher voltage one will be burnt the diode.
LED has an direction for electrical current. Therefore try reverse connection if there is no lighting.