INSPECTION
CAUTION:
All measuring instruments should be handled with special care, or the correct measurement is impossible.
On an instrument powered by dry batteries, the latter should be checked for voltage periodically and replaced, if necessary.
NOTE:
" O ---- O " indicates the terminals between which there is a continuity of electricity; i.e., a closed circuit at the respective switch position.
Peak voltage measurement
NOTE:
- The coil output varies greatly at cranking speed.
- Cranking a cold engine with the plugs in and a weak battery does not enable proper readings.
Digital multimeter: J-39299
Peak volt adapter: YU-39991
Low resistance measurement
When measuring a resistance of 10 Ω or less using the digital tester, the correct measurement cannot be obtained because of the tester's internal resistance.
To obtain the correct value, subtract this internal resistance from the displayed measurement.
Correct value = Displayed measurement - Internal resistance
NOTE:
The internal resistance of the tester can be obtained by connecting both of its terminals.