REMOVING/INSTALLING THE POWER TRIM AND TILT UNIT

| Order | Job/Part | Q'ty | Remarks |
|---|---|---|---|
| Tilt up the outboard | |||
| 1 | Plastic locking tie | 3 | Not reusable |
| 2 | Power trim and tilt lead | 2 | |
| 3 | Bolt | 1 | |
| 4 | Ground lead | 1 | |
| 5 | Circlip | 1 | |
| 6 | Upper mounting pin | 1 | |
| Continued on next page. |

| Order | Job/Part | Q'ty | Remarks |
|---|---|---|---|
| 7 | Bolt | 2 | |
| 8 | Washer | 2 | |
| 9 | Lower mounting pin | 1 | |
| 10 | Power trim and tilt unit | 1 | |
| 11 | Collar | 6 | |
| For installation, reverse the removal procedure. |
REMOVING THE POWER TRIM AND TILT UNIT
WARNING
After tilting up the outboard, be sure to support it with the tilt stop levers.
Otherwise, the outboard could suddenly lower if the power trim and tilt unit should lose fluid pressure.
NOTE:
Tilt up the outboard and then turn the tilt stop levers (1) to support it.
Remove:
- Power trim and tilt unit
NOTE:
Slightly lower the tilt ram assembly and then remove the power trim and tilt unit.

BLEEDING THE POWER TRIM AND TILT UNIT (ON OUTBOARD)

NOTE:
Install the power trim and tilt unit onto the outboard before bleeding.
Bleed:
- Air bubbles
(from the power trim and tilt unit)
Bleeding steps
(1) Connect the battery leads to the battery.
(2) Loosen the manual valve (1) by turning it counterclockwise until it stops.

(3) Tilt up the outboard fully, then release it, and let it lower by its own weight.
(4) Tighten the manual valve by turning it clockwise.
(5) Let the power trim and tilt fluid settle for about 5 minutes.
(6) Push and hold the power trim and tilt switch in the up position until the out board is fully tilted up.
(7) Turn the tilt stop levers to support the outboard. Then, let the power trim and tilt fluid settle for about 5 minutes.
(8) Remove the reservoir cap (2) and check that fluid is up to the brim as shown. Add fluid if the level is below the brim.
(9) Install the power trim and tilt reservoir cap.
(10) Repeat the above steps two or three times until the power trim and tilt fluid is at the correct level.