PREPARE FOR WINTER: 10-50% discount on all OEM parts!

Unless prohibited by manufacturer. Does not include aftermarket or Crowley Marine branded products. Priced as marked.

Our warehouses are closed on Thursday and Friday, November 26th and 27th. Happy Thanksgiving!

Search Over 1 Million OEM Parts
Easy-to-use  parts diagrams Best price  guarantee Expert  live support 50+ years  of serving boaters Huge selection of OEM parts  -  from 1950 to 2026 Most parts in stock  -  Same day fulfillment
Most parts in stock- Same day fulfillment

Specifications [Maintenance Specifications] [1993]

Related Products:

Applicable Models

Model group Year Model Serial
Yamaha Outboard 1993 115hp All
Yamaha Outboard 1993 150hp All
Yamaha Outboard 1993 175hp All
Yamaha Outboard 1993 200hp All
Yamaha Outboard 1993 130hp All
Yamaha Outboard 1993 225hp All

Specifications [Maintenance Specifications] [1993]
LIT-18616-00-93
Yamaha Marine

MAINTENANCE SPECIFICATIONS

ENGINE

  • 1 : (S) Starboard, (P) Port

  • 1 : (S.M) Starboard Middle
    (S) Starboard, (P) Port

LOWER

ELECTRICAL

CDI unit:
CDI unit resistance chart

CDI resistance values will vary from meter to meter, especially with electronic digital meters. For some testers, polarity of leads is reversed.

B : Black

Br : Brown

L : Blue

R : Red

B/R : Black/Red

B/W: Black/White

W/B: White/Black

W/G: White/Green

W/R: White/Red

W/Y : White/Yellow

For Charge Coil

For Pulser Coil

For Ignition Coil
B/W—B: 2.4-6.5 kΩ

CDI unit resistance chart

CDI resistance values will vary from meter to meter, especially with electronic digital meters. For some testers, polarity of leads is reversed.

B : Black

Br: Brown

L : Blue

R : Red

B/R : Black/Red

B/W : Black/White

W/B : White/Black

W/Br: White/Brown

W/G : White/Green

W/L : White/Blue

W/R : White/Red

W/Y : White/Yellow

For Charge Coil

For Pulser Coil

For Ignition Coil
B/W—B: 2.4 ~6.5 kS2

CDI unit resistance chart

CDI resistance values will vary from meter to meter, especially with electronic digital meters. For some testers, polarity of leads is reversed.

B : Black

Br: Brown

G : Green

L : Blue

R :Red

B/R : Black/Red

B/W :Black/White

W/B :White/Black

W/Br: White/Brown

W/G : White/Green

W/L : White/Blue

W/R : White/Red

W/Y : White/Yellow

For Charge Coil

For Pulser Coil

For Ignition Coil
B/W—B: 2.4-6.5 kΩ

For Crank Position Sensor

Oil pump control unit

1. These measurements should be made only when the engine is tilted more than 35 degrees.

  1. Hold emergency switch on "ON”.

(Built in CDI unit)

TIGHTENING TORQUE

  • V4 : 115, P115, 130, L130
  • V6 : 150, L150, P150, 175, 200, L200, P200, 225

DIMENSION 1

DIMENSION 2