Service Manual G2 74° V6 Service Manual 5010014 Oiling System [Break-In Oiling]

Related Products:
Service Manual G2 74° V6 Service Manual 5010014 Oiling System [Break-In Oiling]
5010014
BRP Marine

Oil Recirculation System

External hoses and fittings, internal cylinder/crankcase passages, and intake manifold pas sages are used to recirculate any accumulation of oil from various locations in the powerhead. The movement of oil is controlled by check valves.

Crankcase / Main Bearing Recirculation

The movement of oil through the main bearings is controlled by internal passages, external fittings and hoses, and an in-line check valve.

Both center main bearings receive oil through grooved passages in the crankcase. Oil migrates to the bearings from the crankcase areas of the higher cylinders.

The lower main bearing receives oil through:

  • a check valve and internal passage from the area inside the plenum
  • a check valve and external hose from the reed plate of cylinder number 4
  • a check valve and internal passage from the reed plate of cylinder number 5
  • a check valve and internal passage from the reed plate of cylinder number 6

The upper main bearing receives oil through a check valve and external hose from the reed plate of cylinder number 2.

Lower to upper main bearing oil flow

Oil moves from the lower main bearing cavity through an internal crankcase passage to an external fitting. External hoses with an in-line check valve connect to a fitting at the upper main bearing, which leads to the upper main bearing through an internal crankcase passage.

Break-In Oiling

The operator must monitor the oil tank level to confirm oil consumption. This may require several hours of operation above idle.

IMPORTANT: DO NOT add oil to the fuel tank on Evinrude E-TEC models.

The EMM automatically supplies extra oil to the engine for the first two hours above 2000 RPM.

Follow these steps for outboard set-up:

  • Use Evinrude Diagnostics software, v 6.1 or higher to make sure the break-in program has been started.
  • Use the diagnostics software to start break-in oiling after a powerhead rebuild.