Shift Actuator
Control Circuit Tests
Use appropriate test leads or adapters such as Test Probe Kit, P/N 342677, when performing electrical tests.
NEVER pierce the insulation of the engine wiring, or use any piercing-style test probe. Piercing insulation damages the wire and can cause other unintended electrical problems.
Circuit tests check the integrity of the main engine harness and EMM circuits using resistance or diode tests. Continuity tests check the integrity of ground circuits and/or the 55V circuit. These tests eliminate the need to disconnect the engine harness from the EMM, or remove the EMM.
Remove the electrical connector from the shift actuator.
Make sure the key switch is OFF.
Use the diode test function of a digital multimeter to check the shift actuator circuits. Use an appropriate test probe lead to connect the negative meter lead to the wire listed in the table, connect the positive meter lead to an engine ground.

- Engine harness connector (shift actuator)
| Shift Actuator Circuit Diode Test |
|---|
| Wire | Pin | Result |
|---|---|---|
| Yellow/Blue | 1 | approximately 0.5 VDC |
| Yellow/Green | 2 | approximately 0.5 VDC |
| Red/White | 3 | 0.11 to 0.125 VDC |
| Yellow/Black | 4 | 2.1± 0.5 VDC |
Results:
- No reading (OL or ∞) indicates an open circuit.
- A reading of zero (0) indicates an short circuit. Isolate the faulty component. Check wiring and connections. Repair or replace faulty wiring.
Shift Actuator Ground Circuit
Use a digital multimeter with appropriate test probe leads to measure the ground circuit resistance. Connect the positive meter lead to the engine harness connector wire listed in the table. Connect the negative meter lead to engine ground.
| Shift Actuator Ground Circuit Resistance |
|---|
| Wire | Pin | Result |
|---|---|---|
| Black/White | 5 | < 1 Ω |
Results:
An infinite reading (∞) indicates an open circuit. Isolate the faulty component. Check wiring and connections. Repair or replace faulty wiring.
Neutral Circuit
There are no tests for the neutral circuit.