TROUBLESHOOTING
Before starting troubleshooting, read and follow the “PRECAUTION ON SYSTEM INSPECTION”
section on the page 3-36.
In this section, troubleshooting procedures are based on the assumption that “low pressure fuel system” and
“mechanical components (power unit, lower unit, etc.)” are normal.
For troubleshooting of “Starter motor will not run”, see the page 4-6.
CHART 1: SELF-DIAGNOSTIC CODE “3-4”

CHART 2: SELF-DIAGNOSTIC CODE “4-2”

CHART 3: SELF-DIAGNOSTIC CODE “3-1”

CHART 4: SELF-DIAGNOSTIC CODE “2-4”

CHART 5: SELF-DIAGNOSTIC CODE “2-2”

CHART 6: SELF-DIAGNOSTIC CODE “1-4”

CHART 7: SELF-DIAGNOSTIC CODE “2-3”

CHART 8: SELF-DIAGNOSTIC CODE “3-2”

CHART 9: SELF-DIAGNOSTIC CODE “1-1”

This self-diagnostic code indication may be canceled by turning the ignition switch ON because the ECM detects battery voltage.
It is difficult to check the rectifier & regulator completely. Before replacing with new one, check if its ground
point has good electrical contact.
CHART 10: SELF-DIAGNOSTIC CODE “1-5”

CHART 11: SELF-DIAGNOSTIC CODE “4-3”

CHART12: ENGINE CRANKED, BUT NOT START (OR STOPS SHORTLY AFTER STARTING)
Before starting this troubleshooting, make sure that:
• There is no self-diagnostic code indication.
• Emergency stop switch plate is set in place.

CHART 13: UNSTABLE IDLING/TROLLING (OR ENGINE TENDS TO STALL)
Before starting this troubleshooting, make sure that:
• There is no self-diagnostic code indication.

If the neutral switch has failed (while engine running), the engine will tend to stall when shifting into gear.
If the neutral switch has failed as “always ON”, the engine speed is limited to 3 000 r/min by intermittent fuel
injection and ignition timing is fixed at BTDC 9°. If the neutral switch has failed as “always OFF”, the engine can not cranked.
If the CTP switch has failed, the engine will tend to stall when decelerating.
• The self-diagnostic code “3-1” may not be indicated because the IAC valve condition depends on the ECM control. (See the page 3-29.)
• If the IAC valve has failed, “Fast-idle function (warm-up mode)” won’t operate.