ECM
The program (internal circuit) of ECM has been changed. This change is performed by following reason:
- Accommodation of the optional digital gauges (Teleflex gauges).

| Part Name | Early (’07 model) Part Number | Interchange ability | Late (’08 model) Part Number |
|---|---|---|---|
| ECM (DF60_E01) | 33920-99E53 | Yes ← → No | 33920-99E54 |
| ECM (DF60_E03) | 33920-99E73 | Yes ← → No | 33920-99E74 |
| ECM (DF70_E01) | 33920-99E63 | Yes ← → No | 33920-99E64 |
| ECM (DF70_E03, E40) | 33920-99E83 | Yes ← → No | 33920-99E84 |
WIRING HARNESS

The shape of the SDS communication connector has been changed, as shown in the figure, to connect SDS-Ver.5 with out conversion harness.
The optional digital gauge operating signal is output from the three lead wires in this connector. For this reason, when the optional gauge (Teleflex gauge) is used, the connector A for the standard gauge in the wiring harness in the figure should be connect with the SDS communication connector.