THERMOSTAT

REMOVAL
- Disconnect water hose (1) from thermostat cover.
- Remove the four (4) bolts (2) securing the thermostat cover, then remove the cover (3) and thermostat (4).

INSPECTION
- If salt deposits, corrosion, wear or other damage is found, clean or replace.

Thermostat operation
Check thermostat opening temperature as follows :Insert a length of thread between thermostat valve / body and suspend thermostat in a container filled with water.
Place thermometer in container and heat water.
Observe water temperature when thermostat valve opens and releases thread.
Thermostat operating temperature
Standard : 48 – 52 °C (118 – 126 °F)

INSTALLATION
Installation is reverse order of removal with special attention to the following steps.

- Assemble thermostat (1), gasket (2) and thermostat cover (3) to cylinder head block and secure with bolts.