CRANKCASE

CRANKCASE BOLT

The surface treatment of the crankcase bolt has been changed.

The tightening of the case bolts is performed in three stages.

However, with this change effected, the torque specification for the second tightening stage has been changed. The torque specifications for the first and the final tightening remains
unchanged.

Crankcase bolt tightening torque
2nd step 10 mm 37 N·m → 23 N·m
2nd step 8 mm 20 N·m → 13 N·m

CRANKCASE TO CYLINDER

  1. Clean mating surface of cylinder and crankcase.
  2. Apply sealant to mating surface of crankcase as shown.

Apply sealant to mating surface only.
Do not allow sealant to contact surface of bearing.

  1. Install four (4) dowel pins (1).