Service Manual DF40, DF50 Inspection For Ecm Circuit Voltage [74][Df40, Df50]

Related Products:
Service Manual DF40, DF50 Inspection For Ecm Circuit Voltage [74][Df40, Df50]
99500-87J08-01E
Suzuki Marine

INSPECTION

PRECAUTION ON SYSTEM INSPECTION

To prevent an unexpected engine start, perform the following before proceeding with any CRANKING tests.
• When performing tests not related to fuel injector operation :
  • Disconnect all fuel injector wire connectors.
• When performing tests related to fuel injector operation :
  • Relieve fuel pressure in line. (See page 5-2.)
  • Disconnect high pressure fuel pump wire connector located on fuel vapor separator.

• Always turn ignition switch “OFF” and disconnect battery cables when wires are being disconnected or connected.
• Hold and pull connector pieces when disconnecting. Do not pull wires.

• The self-diagnostic code memory in ECM will remain even if battery is disconnected.
• As each terminal voltage is affected by battery voltage, use a full-charged battery.
• Make sure all ground points have good electrical contact.
• Make sure all wires/cables are securely connected.

INSPECTION FOR ECM CIRCUIT VOLTAGE

ECM cannot be bench checked. It is strictly prohibited to connect any tester (voltmeter or ohmmeter) to an ECM separated from the engine wiring harness.

09930-89910 : 4-pin test cord – (1)
09930-89920 : 6-pin test cord – (2)
09930-89930 : 8-pin test cord – (3)
09930-89940 : 12-pin test cord – (4)
09930-99320 : Digital tester

Tester range : V (DC voltage)

(1) Connect the test cord (1), (2), (3) or (4) between ECM and wire harness as shown.
(2) Turn ignition switch ON.
(3) Connect the tester probe (-) (Black) to body ground, and measure voltage according to the “CIRCUIT VOLTAGE TABLE”.

CIRCUIT VOLTAGE TABLE