Service Manual DF40, DF50 Inspection [84][Df40, Df50]

Related Products:
Service Manual DF40, DF50 Inspection [84][Df40, Df50]
99500-87J08-01E
Suzuki Marine

INSPECTION

BATTERY CHARGE COIL

Measure battery charge coil resistance.

09930-99320 : Digital tester
Tester range : Ω (Resistance)

  1. Disconnect battery charge coil leads from rectifier & regulator.

  2. Measure resistance between leads in the combinations shown.

Battery charge coil resistance :

Terminal for tester probe connection Resistance
White 1 to White 2 0.56 – 0.84 Ω
White 2 to White 3 0.56 – 0.84 Ω
White 3 to White 1 0.56 – 0.84 Ω

If measurement exceeds specification, replace battery charge coil.

FUSE CASE / FUSE

09930-99320 : Digital tester
Tester range : (Continuity)

Fuse

  1. Remove the fuse from fuse case.
  2. Inspect fuse and replace with a new 30-amp fuse if needed.

Fuse case

  1. Disconnect all wires of fuse case.
  2. Check continuity between White lead wire with plate terminal and the other two white lead wires.

Tester range : (Continuity)
If no continuity is indicated, replace fuse case.

RECTIFIER & REGULATOR

09930-99320 : Digital tester
Tester range : Ω (Resistance)

  1. Disconnect all lead wires of rectifier & regulator.
  2. Measure resistance between leads in the combinations shown.

The values given below are for a SUZUKI digital tester.
As thyristors, diodes, etc. are used inside this rectifier & regulator, the resistance values will differ when an ohmmeter other than SUZUKI digital tester is used.

Rectifier & regulator resistance :

Unit : MΩ

If measurement exceeds specification, replace rectifier & regulator.