STARTING MOTOR
REMOVAL
Prior to removing starter motor:
- Disconnect battery cables from battery.

Remove three bolts, two fastening bands and flywheel cover.

Remove bolt and silencer cover.
Disconnect lead wire connector from IAT sensor.

Remove nut and IAC valve from electric parts holder.
Remove starter motor sub cable.
INSTALLATION

Installation is reverse order of removal with special attention to the following steps.
- Install starter motor and tighten starter motor mounting bolts securely.
Starter motor mounting bolt :
23 N·m (2.3 kg-m, 16.5 lb-ft)