Service Manual DF200AP Power Head[Fuel System[Service Instructions][Fuel Line Inspection]]

Related Products:
Service Manual DF200AP Power Head[Fuel System[Service Instructions][Fuel Line Inspection]]
99500-96L10-01E
Suzuki Marine

Fuel Line Inspection

Visually inspect fuel lines for evidence of fuel leakage, cracking, deterioration, or damage. Make sure all clamps are secure. Replace parts as needed.

Fuel Leakage Check Procedure

After performing any fuel system service, always be sure there is no fuel leakage by checking as follows.

  1. Squeeze fuel primer bulb until you feel resistance.
  2. Shift into “Neutral” position.
  3. Ensure emergency stop switch lock plate is in place.
  4. Turn main switch “ON” for 3 seconds (to operate fuel pump), then turn it “OFF”.
    Repeat this (“ON” and “OFF”) procedure 3 or 4 times to pressurize the fuel system.
  5. Once pressurized, check all connections and components for any signs of leakage.

Inspection of Fuel Hose Connections

Note that the fuel hose connection varies with each type of pipe. Be sure to connect and clamp each hose correctly by referring to the figure.
• For type “A” (short barbed end) pipe, the hose must completely cover pipe.

Type “A”

1. Clamp (Clip) 3. Joint pipe
2. Hose “a”: 3 – 7 mm (0.1 – 0.3 in)

• For type “B” (bent end) pipe, hose must cover the straight part of pipe by 20 – 30 mm (0.8 – 1.2 in.).

Type “B”

“a”: 3 – 7 mm (0.1 – 0.3 in) “b”: 20 – 30 mm (0.8 – 1.2 in)

• For type “C” pipe, hose must fit up against the flanged part of pipe.

Type “C”

“a”: 3 – 7 mm (0.1 – 0.3 in)

• For type “D” pipe, the hose must cover the pipe by 20 – 30 mm (0.8 – 1.2 in.).

Type “D”

“a”: 3 – 7 mm (0.1 – 0.3 in) “b”: 20 – 30 mm (0.8 – 1.2 in)