Service Manual DF200AP Power Head[Engine Control[Diagnostic Information And Procedures][Self-Diagnostic Code “5 – 1” Vvt Advance]]

Related Products:
Service Manual DF200AP Power Head[Engine Control[Diagnostic Information And Procedures][Self-Diagnostic Code “5 – 1” Vvt Advance]]
99500-96L10-01E
Suzuki Marine

Self-Diagnostic Code “5 — 1” VVT Advance

Wiring Diagram

1. OCV

Troubleshooting

Step 1

  1. With the main switch “OFF", disconnect the connector from OCV.

  2. Check the voltage at “Gr" wire terminal with the main switch “ON”.

Is the voltage 12 V (battery voltage)?

Yes Go to step 2.

No

  • Power circuit open.
  • ”Gr” wire shorted to “Br/W” wire or ground circuit.
  • If the wiring and connection is OK, substitute known-good ECM and recheck.

Step 2

  1. Inspect OCV and OCV gasket filter condition.
    Refer to “OCV (Oil Control Valve) Inspection" in Section 1C (Page 1C-21).

Is the result 0K?

Yes

  • Poor OCV connection, intermittent trouble or a faulty ECM.
  • Clogged OCV oil passage.

No Faulty OCV.