GEAR CASE LEAK TEST
Drain lubricant before testing.
Use Gear case Pressure Tester, P/N 507977. Install lubricant drain/fill plug and seal, thread pressure test gauge fitting and seal in lubricant level hole.
Pressurize 3 to 6 psi (21 to 42 kPa).
If pressure gauge indicates leakage, submerge the gear case in water to determine source of leak. If the gauge does not indicate leakage, increase pressure to 16 to 18 psi (110 to 124 kPa). Check for leaks.
Make necessary repairs and repeat test.
Install Gear case Vacuum Tester, P/N 507982. Apply 3 to 5 in. of vacuum (76 to 127 mm) Hg. with pump.
If vacuum gauge indicates leakage, apply oil around suspected seal. If leak stops or oil is drawn in, seal is defective.
Repeat test, gear case must hold minimum of 15 in. vacuum (381 mm) Hg.

GEAR CASE REMOVAL AND INSTALLATION
Gear case Removal
To prevent accidental starting while servicing, twist and remove all spark plug leads. During service, the outboard may drop unexpectedly. Avoid personal injury; always support the outboard’s weight with a suitable hoist or the tilt support bracket during service.
Remove pin and washer from shift rod lever to release the lower shift rod.

- Shift rod screw
MRL MODELS
Note where the index mark on the gear case aligns with the index number of the adjustable trim tab so the trim tab can be installed in the same position. Remove the trim tab retaining screw and trim tab from the gear case.

- Trim tab 001996
- Trim tab retaining screw
Remove the forward screw with washer and recessed retaining screw.

Forward screw
Recessed screw
Forward screw 001995 2. Recessed screw
MJRL MODELS
Remove the impeller housing and impeller assembly. Refer to IMPELLER SERVICE, MJRL MODELS on p. 236.
Remove the recessed retaining screw from the gear case.

- Screw
Remove nut and washer.

- Nut
ALL MODELS
Remove the four gear case retaining screws.

- Gear case retaining screws
Remove the gear case assembly from the exhaust housing, being careful not to bend the shift rod.
Gear case Installation
During service, the outboard may drop unexpectedly. Avoid personal injury; always support the outboard’s weight with a suitable hoist or the tilt support bracket during service.
Before installing gear case, shift rod adjustment MUST be checked. Refer to SHIFT ROD ADJUSTMENT on p. 244.
Coat the driveshaft splines with Moly Lube. DO NOT coat top surface of the driveshaft because lubricant may prevent seating of the driveshaft in the crankshaft.

Apply Adhesive 847 to the exhaust housing seal’s outer surface. Place the seal in the gear case exhaust cavity. Apply Triple-Guard grease to the seal’s inner surfaces.

- Exhaust housing seal
Slide the gear case into place, making sure:
- Driveshaft engages the crankshaft—rotate fly wheel if necessary
- Inner exhaust housing installs correctly
- Shift rod does not turn and is positioned properly in shift shaft connection area.
Apply Triple-Guard grease to threads of the gear case retaining screws. Tighten the screws to a torque of:
• 3/8 in. screws – 18 to 20 ft. lbs. (24 to 27 N·m)
• 7/16 in. screw – 28 to 30 ft. lbs. (38 to 40 N·m)
• 5/16 in. screw – 10 to 12 ft. lbs. (13.5 to 16 N·m)

- 3/8 in. screws 001994

- 7/16 in. screw
- 5/16 in screw
MRL MODELS
Apply Triple-Guard grease to threads of the trim tab screw. Install and align the trim tab with the index marks noted prior to disassembly. Tighten the trim tab screw to a torque of 35 to 40 ft. lbs. (47 to 54 N·m). For adjustment, refer to Trim Tab
Adjustment (MRL) on p. 44.

- Trim tab screw 001996
MJRL MODELS
Install nut and washer. Tighten to a torque of 28 to 30 ft. lbs. (38 to 40 N·m).

- Nut
Install recessed retaining screw. Tighten to a torque of 10 to 12 ft. lbs. (13.5 to 16 N·m).

- Exhaust pipe
- Retaining screw
Install the impeller assembly and impeller housing. Refer to IMPELLER SERVICE, MJRL MODELS on p. 236.
Place the shift rod in the shift rod lever. Install the retaining pin and washer. Tighten pin to a torque of 60 to 84 in. lbs. (7 to 9.5 N·m).

- Shift rod screw
To prevent loss of operator control, check for proper shifting operation and adjust, if necessary
IMPORTANT: During break-in period of a reassembled gear case, change the gear case lubricant between 10 to 20 hours of operation.