Service Manual 115-200 HP E-TEC Trim And Tilt
Fill the oil reservoir up to the fill plug with Evinrude/Johnson Biodegradable TNT Fluid. Install the fill plug.

004278
1.Reservoir cap
Run the motor, then recheck oil level. Cycle the unit several times and check the oil level when the cylinder is fully extended. Oil should be level with bottom of fill port. Install and tighten the fill plug to a torque of 45 to 55 in. lbs. (5 to 6 N•m).
ADJUSTMENTS
Refer to Trim Sending Unit Adjustment on p. 80.
Refer to Tilt Limit Switch Adjustment on p. 79