EXPLODED DIAGRAM
| 40MH | ✓ |
|---|---|
| 40ER | |
| 40PR | |
| 40TR | |
| 50ER | |
| 50TH | |
| P50TR |
(1) Starter case
(2) Starter spring
(3) Sheave drum
(4) Starter stop plunger
(5) Starter handle
(6) Cover
(7) Seal
(8) Rope guide
(9) Drive pawl spring
(10) Drive pawl
(11) Bushing
(12) Starter pully
(13) Hole cover gasket

REMOVAL AND DISASSEMBLY
1) Remove and disassemble the recoil starter referring to the exploded diagram. Note the following points.
Remove the start-in-gear protection device at the recoil starter.
When removing the starter rope, insert a screwdriver into the starter stop-plunger hole to secure the sheave-drum from running off.
Slowly turn the sheave-drum clockwise to spring-free, and remove the sheave-drum.

NOTE:
When removing the sheave drum, hold down the starter spring so that the starter spring will not spring out.
WARNING:
Wear suitable protective gloves and take care to protect yourself from an accident due to the spring flying out when removing the sheave drum.
- Holding the spring with one hand, unfold the spring from its center with the other. Be careful the spring does not jump out.
WARNING:
When removing or installing the starter spring, use care not to injure your hand. It is advisable to wear gloves.

INSPECTION
H12000 0

Drive pawl and spring
1) Visually inspect the drive pawl for breaks bends, or wear and, if these are found, replace the things.
Collar and roller
1) Visually inspect the collar and roller for wear and, if both or either is worn, replace them as a set.

Sheave drum
1) Visually inspect the sheave drum and sheave pin for damage, cracks or warping and, if these are found, replace the sheave drum.

Bushing
1) Visually inspect the bushing for wear or cracks and replace as required.
Starter rope
1) Visually inspect the starter rope for kinks or fraying and, if any damage is found, replace the starter rope.
WARNING:
Do not use a damaged starter rope which could cause injury.
Starter rope length: 2,095 mm (82.5 in)

Starter spring
1) Visually inspect the starter spring and replace it if it is broken or has distorted ends.

Start-in-gear protection
1) Inspect the starter stop-plunger and replace it if is cracked or damaged.
2) Inspect the cable and replace it if it shows signs of fraying or sticking.
ASSEMBLY
H13000-1

1) Hook the outer end of the starter-spring onto the retainer-post attached to the starter-case, and install the spring onto the starter case by winding it counterclockwise.
Water resistant grease
NOTE:
- Apply water resistant grease (All-Purpose) to the inner surface of the starter case.
- Each new starter-spring is bound by a steel hoop. To install, hook its outer end onto the retainer-post first, put it into the starter case, and then remove steel hoop.
2) Insert the rope through the rope-holes, and knot the ends.
WARNING
Do not use a damaged starter rope, it could cause injury.
3) Wind the rope 1-9/10 turns on to the sheave drum.
4) Place the rope at the cutaway.
5) Position the inner end of the starter-spring on the retainer-post of the sheave-drum.

6) Install the busing to the starter-case.
Water resistant grease
NOTE:
Apply water resistant grease (All-Purpose) to the outer surface of the bushing.
7) Pass the starter-rope through the cut.
8) Wind-up the spring 2.5 turns counterclockwise with the starter-rope.

9) Install the roller, the collar and the rope-guide.
Water resistant grease
NOTE:
Apply water resistant grease (All-Purpose) to the collar.

10) Hook the drive-pawl spring onto the drive pawl, install the drive-pawl on the starter-case boss, and then hook the drive-pawl onto the bushing.
Water resistant grease

NOTE:
Apply water resistant grease (All-Purpose) to the pawl-drive hole.
11) Secure the drive-pawl with the circlip.

INSTALLATION
H14000 0
Install the starter stop-plunger to the starter case, referring to page 3-22.
Secure the starter assembly to the power unit.