EXPLODED DIAGRAM

REMOVAL AND INSTALLATION CHART
| Step | Procedure/Part name | Q'ty | Service points |
|---|---|---|---|
| OIL FILTER, THERMOSTAT AND EXHAUST COVER REMOVAL | Follow the left "Step" for removal | ||
| 1 | Oil filter | 1 | |
| 2 | Oil filter plug | 1 | |
| 3 | Bolt (thermostat cover) | 2 | M6 x 30 mm |
| 4 | Thermostat cover | 1 | |
| 5 | Gasket (thermostat) | 1 | Not reusable |
| 6 | Thermostat | 1 | |
| 7 | Bolt (exhaust cover) | 5 | M6 x30 mm |
| 8 | Exhaust cover | 1 | |
| 9 | Gasket (exhaust cover) | 1 | |
| 10 | Bolt (breather cover) | 3 | M6 x20 mm |
| 11 | Breather cover | 1 | |
| 12 | Gasket (breather cover) | 1 | Not reusable |

REMOVAL AND INSTALLATION CHART
| Step | Procedure/Part name | Q'ty | Service points |
|---|---|---|---|
| 13 | Bolt (plate) | 1 | |
| 14 | Plate | 1 | |
| 15 | Anode cover | 1 | NOTE: |
| Remove with the ass'y. | |||
| 16 | Bolt (anode cover) | 1 | |
| 17 | Rubber packing | 1 | NOTE: |
| Apply oil on the outer surface. | |||
| 18 | Anode | 1 | |
| Reverse the removal steps for installation |
SERVICE POINTS


Thermostat inspection
- Measure:
- Valve operating temperature
- Valve lift (a)
Out of specification —> Replace the thermostat
| Water temperature | Valve lift |
|---|---|
| Below 60°C (140°F) | 0 mm (0 in) |
| Above 70°C (158°F) | 3 mm(0.12 in) |
Measuring steps:
- Suspend the thermostat in a container filled with water.
- Slowly heat the water.
- Place a thermometer in the water.
- While stirring the water, observe the thermometer’s indicated temperature.
Anode inspection
- Inspect:
- Anode
Refer to the "ANODE" in chapter 3. 5-33