EXPLODED DIAGRAM

| Step | Procedure/Part name | Q’ty | Service points |
|---|---|---|---|
| ELECTRICAL UNIT REMOVAL | Follow the left "Step" for removal. | ||
| 1 | Battery cable | 2 | |
| 2 | 2 Battery (+) lead coupler | 1 | |
| 3 | Bolt | 1 | 6 x 12 mm |
| 4 | Ground lead | 2 | |
| 5 | Stator lead coupler | 7 | |
| 6 | Stop switch lead coupler | 1 | Except for electric starter model |
| 7 | Oil level sensor lead coupler | 1 | Oil injection model |
| 8 | Warning lamp lead coupler | 2 | |
| 9 | Starter switch lead coupler | 2 | Manual & Electric starter mode |
| 10 | Bolt | 2 | 6 x 45 mm |
| 11 | Bolt | 3 | 6 x 30 mm |
| Reverse the removal steps for installation. |
[A] : Manual & Electric starter model
[B] : Electric starter model