TEST PROPELLER
Whenever the motor is tested (for instance, before it is delivered to the customer or after being overhauled) be sure to use a test tank and test propeller. If the originally mounted propeller is used, the test tank may overflow or the water level may fluctuate sharply, thus causing cavitation with a marked increase in rpm or propeller slip. Therefore, it is impossible to check if the motor has been correctly overhauled. The test propeller is designed to turns stably even in the test tank. If the tachometer readings are within the specified speed range when the motor is run with the test propeller, the motor is considered to be properly serviced. If the engine speed is far below the specified speed, the motor will have to be checked again.
Specified motor speed: (Wide open throttle) 4,900 5,100 min¯¹ (r/min)