Step 1: CABLE AND HOSE INSTALLATION
Before installation, identify all required wiring, cables, and hoses:
- Throttle and shift cables
- Instrument harnesses
- Battery cables and switches
- Fuel supply hose
- Primer bulb or primer pump
Determine whether any additional wiring or hoses will be needed for accessory gauges or batteries:
- Speedometer pick-up hose
- Mechanical water pressure gauge hose

Typical outboard installation
- Anti-siphon valve
- Water separating fuel filter
- Starting battery
- Accessory battery
- Flexweave protective sleeve
- Access cover
- Primer bulb
- Battery switch
Step 2: Boat Cable and Harness Routing
Improper installation and routing of outboard controls could wear, bind, and damage components, causing loss of control.
Remote control cables, wiring, and hoses must follow a similar path into the lower motor covers. Select the best routing for the specific application.
All cables, wiring, and hoses must be long enough to provide adequate slack. Check clearances at all possible combinations of trim angles and steering positions.

Typical Small Splash Well

Typical Large Splash Well
Step 3: Battery Cables
When routing battery cables, be sure to:
- Route cables through the battery cable grommet.
- Use the most direct path to route the battery cables to the battery or battery switch.
Step 4: Fuel Hose
Route fuel hoses with enough slack to allow the primer bulb arrow to point “up” during use.
Install the primer bulb with the arrow pointing in the direction of fuel flow to the outboard.
Connect the fuel supply hose from the fuel tank to the fuel quick connect fitting at the outboard.
Step 5: Oetiker Clamp Servicing

- Clamp identification numbers
Clamp Identification
Use Oetiker clamps for making hose connections. These clamps provide corrosion resistance, minimize the potential for abrasion of rigging components, and provide solid, permanent connections.
The selection and installation of an Oetiker clamp is essential in the proper sealing of hose connections. The clamp identification numbers appear on the side of the clamp, near the top of the ear. Refer to Clamp Selection chart for dimensions.
DO NOT re-use Oetiker clamps. Fuel leakage could contribute to a fire or explosion.
Clamp Selection
To select the correct size Oetiker clamp, measure the outside diameter of the hose when installed on the fitting.
Chose a clamp so that the outside diameter of the the outside diameter of the hose is approximately in the middle of the clamping range of the clamp.

Clamp Installation
A constant stress should be applied to close the ear clamps. This method ensures a positive stress on the hose and does not result in excessive compression or expansion of the band material.
IMPORTANT: Use only Oetiker recommended tools to close Oetiker stepless clamps.
Oetiker pincers are available in the Evinrude/Johnson Genuine Parts and Accessories Catalog.

- Position correct size clamp over hose.
- Install hose on fitting.
- Close clamp ear fully with Oetiker pincers (pliers).

- Open clamp
- Closed clamp
Clamp Removal
Method 1: Position Oetiker pincers across clamp ear and cut clamp.

Method 2: Lift end of stepless clamp with screwdriver.

Method 3: Use Oetiker pincers (pliers) to grip clamp. Pull clamp off of connection and discard.