Our warehouses are closed on November 26th and 27th. Happy Thanksgiving!

Search Over 1 Million OEM Parts
Most parts in stock - Same day fulfillment

OE 2011 Evinrude Installation & Predelivery Guide (P-N 5008506) - Technical Specifications Battery Installation [Boat Rigging]

OE 2011 Evinrude Installation & Predelivery Guide (P-N 5008506) - Technical Specifications Battery Installation [Boat Rigging]
Johnson/Evinrude, OMC

BATTERY INSTALLATION

Each outboard requires its own starting battery. Select a battery that meets or exceeds the minimum requirements.

Battery Recommendations

Outboard Model Battery Rating
115–300 HP 675 CCA (845 MCA), or 800 CCA (1000 MCA) below 32°F (0°C)107 amp-hr in extreme applications
15–90 HP 640 CCA (800 MCA), or 800 CCA (1000 MCA) below 32° F (0° C)107 amp-hr in extreme applications

Battery Location

Proper installation will prevent battery movement while underway.

  • Secure all batteries in protected locations

  • Place battery as close to the outboard as possible

  • Battery location must provide access for periodic maintenance

  • Use battery mounting trays or battery boxes on all battery installations

  • Connections and terminals must be covered with an insulator

  • Battery connections must be clean and free from corrosion

  • Read and understand the safety information supplied with the battery before installation.

Battery Connections

Keep the battery connections clean, tight, and insulated to prevent their shorting or arcing and causing an explosion. If the battery mounting system does not cover the connections, install protective covers. Check often to see that connections stay clean and tight.

IMPORTANT: Connect the battery positive (+) cable to the battery positive (+) post FIRST. Connect the battery negative (–) cable to the battery
negative (–) post LAST.

Install a starwasher on the threaded battery post. Stack cables from the outboard, then cables from accessories. Finish this connection with a hex nut.


Marine Style Battery Post

  1. Starwasher
  2. Hex nut
  3. Terminal Insulator

Do not use wing nuts to fasten ANY battery cables. Wing nuts can loosen and cause electrical system damage not covered
under warranty.

Tighten all connections securely. Apply Triple Guard grease to prevent corrosion.

Battery Cable Requirements

Evinrude outboards are shipped with stranded copper battery cables for typical installations in which the starting battery is close to the transom.

Specialized outboard installations with extended length battery cables require an increased wire size. Refer to the following table.

15–30 HP 40–300 HP
1 to 10 Ft.
(.3 to 3 m)
6 Gauge 4 Gauge
11 to 15 Ft.
(3.4 to 4.6 m)
4 Gauge 2 Gauge
16 to 20 Ft.
(4.9 to 6.1 m)
2 Gauge 1 Gauge

IMPORTANT: Inadequate battery cables can affect the performance of an outboard’s high amperage start circuit and the cranking speed of
the outboard. DO NOT use aluminum wire cables. Use ONLY AWG stranded copper wire cables.

Battery Switches and Multiple Batteries

A multiple battery setup, including marine battery selector switches, can provide flexibility in single and dual outboard installations.

Refer to Battery and Switch Wiring Diagrams on p. 18 for battery connection options.

The battery selection function can be used for emergency starting if a primary battery becomes discharged.

The OFF position of the battery selector switch can be used to minimize battery discharge during periods of non-use.

Typical battery functions

Primary

  • Used as starting battery under normal operating
    conditions.

  • Red (+) cable connected to battery switch.

  • Primary battery is charged by connection to main red (+) outboard battery cable. Dual outboard installations can utilize the opposing outboard's primary battery as a secondary battery for emergency starting only.

Secondary

  • Used as back-up starting battery under abnormal operating conditions.

  • Red (+) cable connected to battery switch.

  • Secondary battery is charged independently from primary battery.

Accessory

  • Not used as starting battery.

  • Isolated from outboard start function.

  • No red (+) cable connected to battery switch.

Secondary and accessory batteries are often charged by an isolated battery charging circuit. Refer to Auxiliary Battery Charging on p. 17.

Battery Switch Requirements
Battery switches must meet the following requirements.

  • The switch must be approved for marine use.

  • The switch should be a “make before break” design.

  • Switch amperage rating should be adequate for the outboard it will be used on.

  • Use one battery switch for each outboard
    installed.

  • Use appropriately sized wire and terminals.

  • Use AWG stranded copper wire.

Battery Switch Location

  • Locate battery switch as close to the batteries as possible.

  • Locate switch so that it cannot be accidently bumped or switched.

  • Refer to the battery switch manufacturer’s installation instructions.

  • Fasten all battery switches to solid surfaces.

  • Route wiring as directly as possible.

  • Support the battery switch as needed to prevent
    abrasion.

  • Use appropriate wiring and connectors.

  • Seal all connections and terminals with liquid neoprene to prevent corrosion.

Insulate all battery positive (+) terminals to prevent shorting.

Battery Switch Operation

  • Select the primary battery for normal operation.

  • Secondary batteries should only be selected for emergency starting.

  • ALL or BOTH switch position is for emergency starting only.

Provide operator with the documentation supplied by the battery switch manufacturer. Make sure that the operator is informed of proper battery switch operation.

The negative (–) terminals of a multiple 12-volt battery installation must be connected together.

Auxiliary Battery Charging

EVINRUDE E-TEC V4 – V6 MODELS
Evinrude E-TEC V4–V6 outboards are equipped with isolated battery charging capability. The isolated charge connection must only be used to charge a single 12-volt battery or two 12-volt batteries wired in parallel.

Never connect an external battery isolator to the stator of an Evinrude E-TEC.

Accessory Charge Lead Kit, P/N 5006253, is routed from a connector on the outboard’s electrical harness to the accessory battery.


90° V6 Models

  1. Accessory battery charge connector


60° V4–V6 Models

  1. Accessory battery charge connector

The accessory charging kit must never be connected to any battery of a 24-volt electrical system.

EVINRUDE E-TEC 40 – 90HP MODELS
Evinrude E-TEC 40 – 90 HP outboards do not have a built in isolator feature. Proper methods must be used to connect a second battery.

Battery charging output on 40 – 90 HP models is 25 Amps. Be sure to follow published standards for wire gauge selection. Refer to Battery Cable Requirements on p. 16.

If a battery isolator is desired, a battery switch, such as P/N 506161, and a voltage sensitive relay, such as BEP model 710-125A, can be used to create a battery isolator/combiner.

The voltage sensitive relay (VSR) regulates charging of a second battery based on predetermined voltage levels of the primary battery.

Never connect an external battery isolator to the stator of an Evinrude E-TEC.

Battery and Switch Wiring Diagrams

Single outboard

  1. Single starting battery with ON/OFF switch
  2. Two starting batteries with isolator/combiner (15 – 90 HP models)
  3. Voltage sensitive relay
  4. Two starting batteries with Auxiliary charging kit (V models)

Two outboards: Two starting batteries each

Two outboards: One primary battery each; one isolated accessory battery

Two outboards: One primary battery each; two isolated accessory batteries