REMOVING/INSTALLING THE BEARING HOUSING, SHIFT CAM AND LOWER CASE

| Step | Job/Part | Q'ty | Remarks |
|---|---|---|---|
| 1 | Bearing housing assembly | 1 | |
| 2 | Gasket | 1 | Not reusable |
| 3 | Coller | 1 | |
| 4 | Shift cam | 1 | |
| 5 | Solid bushing | 1 | |
| 6 | Lower case | 1 | |
| 7 | O-ring | 1 | Not reusable |
| 8 | Oil seal | 2 | Not reusable |
| 9 | Solid bushing | 1 | |
| 10 | Bearing housing | 1 | |
| 11 | Dowel pin | ||
| For installation, reverse the removal procedure. |
REMOVING THE SOLID BUSHING

Remove:
- Solid bushing
Driver rod: YB-06229/90890-06652
Attachment: YB-06028/90890-06650
(A)For USA and Canada
(B) Except for USA and Canada
DISASSEMBLING THE BEARING HOUSING

Remove:
- Solid bushing
Driver rod: YB-06229/90890-06652
Bushing attachment: YB-06028/90890-06650
(A) For USA and Canada
(B) Except for USA and Canada
CHECKING THE COLLER
Check:
- Collar
Damage/wear -» Replace.
CHECKING THE SHIFT CAM
CHECKING THE LOWER CASE
- Clean:
- Lower case (with a soft grush and solvent).
- Check:
- Water passage
Mineral deposits/corrosion -> Clean.
- Check:
- Lower case
Cracks/damage Replace.
ASSEMBLING THE BEARING HOUSING

- Install:
- Solid bushing
Driver rod: YB-06229/90890-06652
Attachment: YB-06028/90890-06650

- Install:
- Oil seal
Oil seal mounting depth (a): 6.0 - 6.5 mm (0.236 - 0.256 in)
Driver rod: YB-06071/90890-06652
Attachment: YB-06611/90890-06614
Press fit both oil seals at the same time to the mounting depth.
INSTALLING THE SOLID BUSHING

Install:
- Solid bushing
Bushing installer center bolt (1): YB-06029/90890-06601
Attachment (2): YB-37350/90890-06616
Pull up the solid bushing until the flange is
in tight contact with the lower case.