Fuel System [Oil Tank] [2002]

Related Products:

Applicable Models

Model group Year Model Serial
Yamaha Outboard 1998 - 2003 50hp All
Yamaha Outboard 1998 - 2003 40hp All
Yamaha International 2001 - 2002 40hp All
Yamaha International 2001 50hp All

Fuel System [Oil Tank] [2002]
LIT-18616-01-81
Yamaha Marine

EXPLODED DIAGRAM

REMOVAL AND INSTALLATION CHART

Step Procedure/Part name Q'ty Service points
OIL TANK REMOVAL Follow the left "Step" for removal.
1 Clip 1
2 Oil drain hose 1 NOTE: Drain oil from the oil tank
3 Clip 1
4 Oil inlet hose 1
5 Clip 1
6 Oil return hose 1
7 Oil level sensor lead coupler 1 NOTE: Disconnect the coupler
8 Bolt (with washer) 2
9 Oil level sensor lead 1
10 Bolt (with washer) 1
11 Oil tank ass'y 1
OIL TANK DISASSEMBLY
(1) Oil level sensor 1
(2) Oil strainer 1
(3) Strainer gasket 1
(4) Oil tank cap 1
(5) Hook 1
(6) Hook band 1
(7) Filler tube band 1
(8) Filler tube 1
(9) Special washer 2
(10) Ball chain 1
(11) Special washer 1
(12) Protector 2
(13) Oil return hose 1
(14) Check valve 1
(15) Oil return hose 1
(16) Clip 1
(17) Oil inlet hose 1
(18) Clip 1
(19) Oil drain hose 1
(20) Collar 3
(21) Grommet 3
(22) Oil tank 1
Reverse the removal steps for installation.

OIL LINE LAYOUT

(1) Electrothermal valve (EM, E model)
(2) Oil level sensor
(3) Oil drain hose
(4) Oil tank
(5) Oil pump

SERVICE POINTS

Oil tank inspection

  1. Inspect:
  • Oil tank
    Crack -> Replace.

Oil strainer inspection

  1. Inspect:
  • Oil strainer
    Crack/Clog -> Replace.
    Contamination -> Clean.

Check valve inspection

  1. Check:
  • Check valve operation
    Does not function -> Replace.

Check the operation of the check valve to ensure the air is blown only in the arrow direction.