REMOVING/INSTALLING THE OIL PUMP

| Order | Job/Part | Q'ty | Remarks |
|---|---|---|---|
| 1 | Clip | 1 | |
| 2 | Washer | 1 | |
| 3 | Oil pump link rod | 1 | |
| 4 | Oil hose | 1 | (oil tank-to-oil pump) |
| 5 | Bolt | 2 | |
| 6 | Oil pump | 1 |

| Order | Job/Part | Q'ty | Remarks |
|---|---|---|---|
| 7 | Oil pump drive gear | 1 | |
| 8 | Metal plate | 1 | |
| 9 | O-ring | 1 | |
| 10 | O-ring | 1 | |
| 11 | Clip | 16 | (oil pump-to-intake manifold) |
| 12 | Oil delivery hose | 8 | |
| 13 | Check valve | 4 | |
| For installation, reverse the removal procedure. |
INSPECTING THE CHECK VALVE
Inspect:
- Check valve operation
Damage/reverse air flow → Replace.
Inspecting steps
Do not overpressurize the check valve. Excessive pressure may cause air to leak out.

(1) Install the Mity vac onto the check valve as shown.
Mity vac YB-35956 / 90890-06756
(2) Apply the specified pressure with the Mity vac.
Check valve pressure 80 kPa (0.8 kg/cm², 11.4 psi)
Make sure no air comes out of the opposite side of the check valve.