PREPARE FOR WINTER: 10-50% discount on all OEM parts!

Unless prohibited by manufacturer. Does not include aftermarket or Crowley Marine branded products. Priced as marked.

Our warehouses are closed on Thursday and Friday, November 26th and 27th. Happy Thanksgiving!

Search Over 1 Million OEM Parts
Easy-to-use  parts diagrams Best price  guarantee Expert  live support 50+ years  of serving boaters Huge selection of OEM parts  -  from 1950 to 2026 Most parts in stock  -  Same day fulfillment
Most parts in stock- Same day fulfillment

Electrical Unit [Starting System] [2008]

Related Products:

Applicable Models

Model group Year Model Serial
Yamaha Outboard 2004 - 2005 15hp All
Yamaha Outboard 2004 - 2005 9.9hp All
Yamaha International 2004 - 2005 15hp All
Yamaha International 2004 - 2005 9.9hp All

Electrical Unit [Starting System] [2008]
LIT-18616-02-59
Yamaha Marine

WIRING DIAGRAM

(1) Fuse
(2) 10P coupler
(3) 7P coupler
(4) Main switch
(5) Starter motor
(6) Battery
(7) Starter switch
(8) Neutral switch
(9) Starter relay

[A] Except for remote control model
[B] Remote control model

B : Black
Br : Brown
R : Red

BATTERY

Refer to the "GENERAL" section in chapter 3.

FUSE

  1. Check:
  • Fuse
    Blown -> Replace.

Fuse rating: 12 V - 20 A

WIRING HARNESS

  1. Check:
  • Continuity
    Discontinuity -> Replace.

WIRING CONNECTION

  1. Check:
  • Wiring connection
    Poor connection ->Correct.

ENGINE STOP LANYARD SWITCH

Refer to the "IGNITION SYSTEM" section.

MAIN SWITCH

Refer to the "IGNITION SYSTEM" section.

STARTER SWITCH

  1. Check:
  • Continuity
    Out of specification —> Replace.

NEUTRAL SWITCH

  1. Check:
  • Continuity
    Out of specification -> Replace.

STARTER RELAY

  1. Inspect:
  • Brown lead terminal
  • Black lead terminal
    Loose -> Tighten.

  1. Check:
  • Relay operation
    Does not function -» Replace.

Checking steps:

  • Connect the tester between the terminals of the starter relay as shown.
  • Connect a 12 V battery.

Brown lead (1) -> Positive terminal
Black lead (2) -> Negative terminal

  • Check that there is continuity between the starter relay terminals.