CHECKING THE BATTERY
CHECKING THE FUSES
- Check:
- Fuse holder continuity
No continuity -> Check the fuse holder leads.
- Check:
- Fuse holder lead continuity
No continuity —> Replace the fuse holder.
Continuity -> Check the fuse.

- Check:
- Fuse continuity
No continuity —> Replace. - Fuse rating
Out of specification -> Replace.
Fuse rating
- (1): 12V - 20 A
- (2): 12V - 30 A
MEASURING THE IGNITION COIL ASSEMBLY

Measure:
- Ignition coil assembly resistance
Out of specification -> Replace.
Ignition coil assembly resistance
18.97 - 35.23 kΩ (For cylinder No. 1, 4)
18.55 - 34.45 kΩ (For cylinder No. 2, 3)
CHECKING THE IGNITION SPARK GAP

• Do not touch any of the connections of the spark gap tester lead wires.
• Do not let sparks leak out of the removed spark plug cap.
• Keep flammable gas or liquids away, since this test can produce sparks.
Check:
- Ignition spark gap
Spark is weak —> Check the ignition system.
Checking steps

- (1) Remove the spark plugs from the engine.
- (2) Connect a spark plug cap to the spark gap tester.
- (3) Set the spark gap length on the adjusting knob.
Spark gap tester
YM-34487 / 90890-06754

- (4) Crank the engine and observe the spark through the discharge window of the spark gap tester.
MEASURING THE IGNITION SYSTEM PEAK VOLTAGE
When checking the peak voltage do not touch any of the connections of the digital tester lead wires.
• If there is no spark or the spark is weak, continue with the ignition system test.
• If a good spark is obtained, the problem is not with the ignition system, but possibly with the spark plug(s) or another component.

- Measure:
• The peak voltage adaptor should be used with the digital circuit tester.
• When measuring the peak voltage, set the selector to the DC voltage mode.
Peak voltage adaptor YU-39991 / 90890-03169
- ECM unit output peak voltage
Below specification -> Check the wire harness.
Correct the wire harness -> Replace the ECM unit.
ECM unit output peak voltage
Black/red (B/R) - Ground
Black/white (B/W) - Ground

Test harness (2-pin) 90890-06792

- Measure:
- Pulser coil output peak voltage
Below specification -> Replace the pulser coil.
Pulser coil output peak voltage
White/black (W/B) - Black (B)
White/red (W/R) Black (B)

Test harness (3-pin) 90890-06791