IGNITION CONTROL SYSTEM (PRE-MIXED MODELS)

(1) Thermo switch
(2) CDI unit
B : Black
P : Pink
Gy/B : Gray/black
INSPECTING THE THERMO SWITCH CONTINUITY
Inspect:
• Thermo switch continuity
Out of specification -> Replace.
Thermo switch continuity temperature: Pink (P) - Black (B)
(a) 84 - 90 °C (183-194 °F)
(b) 60 - 74 °C (140- 165 °F)
(1) No continuity
(2) Continuity
[A] Temperature
[B] Time

Measuring steps:
(1) Place the thermo switch in a container filled with water.
(2) Place a thermometer in the water.
(3) Slowly heat the water.
(4) Measure the continuity when the specified temperature is reached.

INSPECTING THE OIL LEVEL SENSOR CONTINUITY
Inspect:
• Oil level sensor continuity
Out of specification —> Replace.


INSPECTING THE EMERGENCY SWITCH
- Inspect:
• Emergency switch continuity
Out of specification -> Replace.
| Switch position | Lead color |
|---|---|
| Switch position | Blue (L) — Black (B) |
| Home (a) | No continuity |
| On (b) | Continuity |
- Inspect:
• Emergency switch
Does not automatically return to the home position -> Replace.

MEASURING THE OIL PUMP CONTROL UNIT
Measure:
• Oil pump control unit resistance
Out of specification -> Replace.